This page was exported from IT Certification Exam Braindumps [ http://blog.braindumpsit.com ] Export date:Thu Apr 10 6:55:21 2025 / +0000 GMT ___________________________________________________ Title: NACE NACE-CIP1-001 Daily Practice Exam New 2023 Updated 100 Questions [Q30-Q47] --------------------------------------------------- NACE NACE-CIP1-001 Daily Practice Exam New 2023 Updated 100 Questions Use Valid NACE-CIP1-001 Exam - Actual Exam Question & Answer The examination covers a wide range of topics, including surface preparation, coating application, inspection techniques, testing methods, and safety procedures. It is a rigorous exam that requires candidates to have a comprehensive understanding of the principles and practices of coating inspection. To be eligible for the exam, candidates must have a minimum of six months of experience in the field and must have completed a NACE-approved training course. Passing the exam requires a score of 70% or higher, and certification is valid for five years. The NACE-CIP1-001 certification is essential for individuals who are seeking to advance their careers in the coating inspection industry and gain recognition for their knowledge and expertise.   NO.30 Digital hygrometers  consist of a bimetallic sensing element protected from wind gusts.  are used to measure temperature from a distance.  use a thermocouple in contact with the surface to measure temperature  determine relative humidity, air temperature, and dew point temperature: NO.31 Prior to using Inspection Tools the inspector must:  Ensure the instrument is within calibration parameters  Be trained on how to use the instrument  Read the manufactures’ instructions  a), b) & c) NO.32 You are the NACE Inspector on a 5000 sq. ft. job where SSPC PA 2 has been specified.Assuming all areas are in compliance, how many gauge readings and spot measurements are required?  105 Gauge Readings resulting in 35 Spot Measurements  75 Gauge Readings resulting in 25 Spot Measurements  225 Gauge Readings resulting in 75 Spot Measurements  45 Gauge readings resulting in 15 Spot Measurements NO.33 Corrosion generally occurs at which of the following sites:  Cathode  Metallic pathway  Electrolyte  Anode NO.34 Prior to the pre-job conference you notice that the Inspection and Test Plan does not require a hold point after surface preparation and coating application. In speaking with the owners’ representative in advance of the meeting you sense he/she does not understand the importance of the hold point.As a NACE CIP Level 1 Inspector your preferred course of action is to:  Gather data and attempt to meet with the owner’s representative in advance of the pre-job conference  Bring the matter up at the pre-job conference  Default to the owner’s Inspection and Test Plan  Meet separately with the coating manufactures’ representative and coating application company in advance of the pre-job conference NO.35 Owners hire NACE Inspectors’ with the expectation that:  The inspection cost will be offset by an improvement in service life  The Inspector will improve job flow and schedule  The Inspector will make a meaningful technical contribution to the job  a) and c) NO.36 To be of value the Inspector’s documentation must be:  Always handwritten  Always typewritten  Timely, accurate and concise  Submitted before the end of the job NO.37 A magnetic pull-off type gauge is a good choice when:  Accuracy is not required  When an intrinsically safe tool is required  Performing an adhesion test  When working on non-ferrous metals NO.38 What is the minimum spot measurement value allowed by SSPC-PA 2 in each 10 m2 (100 ft2) area?  70% of the specified maximum thickness  80% of the specified minimum thickness  90% of the specified maximum thickness  100% of the specified maximum thickness NO.39 It is good practice for the NACE Inspector to have instrument calibration certificates available:  At all times  In the office only  In the field only  Only if the specification requires it NO.40 Inspection documentation is important because:  It is the only deliverable item provided by the inspector  Owners use the documentation for a variety of purposes  a) only  a) & b) NO.41 If the project specification DOES NOT state the specific DFT measurement standards, the inspector should use  a recognized industry standard like SSPC-PA 2 that is broadly accepted  NACE 2/SSPC SP10  their best judgment based on similar projects and specifications.  a detailed checklist and document the lack of a standard. NO.42 Inspector’s daily reports are used:Select All That Apply  By the contractor to estimate the amount of work done that day  To provide continuity between inspectors  To aid in arbitration between the contractor and client  To help in cases of a coating failure NO.43 A single application coating film has a measured dry film thickness (DFT) between 4 and 5 mils (between 100 and 125 microns). The volume solids of the coating immediately before application were 67%, What wet film thickness (WFT) was applied?  5 to 6 mils (125 to 150 microns)  10 to 12 mils (250 to 300 microns)  8 to 10 mils (200 to 250 microns)  6 to 7 mils (150 to 175 microns) NO.44 When applying Thermal Spray Coatings the specification is most likely to refence:  SSPC PA 2  NACE SP 0178  NACE SP 0188  SSPC-CS 23.00/AWS C2.23/NACE No. 12 NO.45 Excess moisture during holiday testing can cause erroneous indications by creating a path across the surface of the coating to pinholes previously detected, or directly to the signal return connection.This is often referred to as:  telegraphing.  monitoring  juxtaposing.  transitioning. NO.46 ISO SA 2.5 is defined as:  Near White Metal Blasting  Thorough Blast Cleaning  Very Thorough Blast Cleaning  Light Blast Cleaning NO.47 You are the NACE Inspector on a tank lining project where a 50% solids epoxy tank lining is being applied. After application of the 19 coat you notice small blisters in some areas of the applied lining.Your FIRST preferred course of action is to:  Break the blisters to see what’s inside  Document the problem and advise the Contractor and Owner’s representative  Document the problem and advise the Contractor  Extract any liquid that may be inside the blister and send it to the lab for further analysis  Loading … Test Engine to Practice NACE-CIP1-001 Test Questions: https://www.braindumpsit.com/NACE-CIP1-001_real-exam.html --------------------------------------------------- Images: https://blog.braindumpsit.com/wp-content/plugins/watu/loading.gif https://blog.braindumpsit.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-04-13 14:41:25 Post date GMT: 2023-04-13 14:41:25 Post modified date: 2023-04-13 14:41:25 Post modified date GMT: 2023-04-13 14:41:25