This page was exported from IT Certification Exam Braindumps [ http://blog.braindumpsit.com ] Export date:Sun Oct 6 12:30:30 2024 / +0000 GMT ___________________________________________________ Title: [2023] Use Valid 300-615 Exam - Actual Exam Question & Answer [Q36-Q59] --------------------------------------------------- [2023] Use Valid 300-615 Exam - Actual Exam Question & Answer Test Engine to Practice 300-615 Test Questions Cisco 300-615 exam is an essential certification exam for IT professionals who work with data center infrastructure. 300-615 exam assesses the candidate's knowledge and skills in troubleshooting Cisco data center infrastructure and covers a broad range of topics related to data center technologies, protocols, and topologies. 300-615 exam is challenging, and the candidates need to prepare well to pass the exam.   QUESTION 36Refer to the exhibit. The EEM script fails to send an SNMP trap when a user attempts to enter configuration mode. Which configuration is missing from the script?  event statement  event-default action statement  policy-default action statement  IP address of the SNMP server Section: AutomationQUESTION 37Refer to the exhibit.The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?  Reconfigure the initiator and the target to be in the same zones.  Reactivate the zoneset.  Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.  Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric. QUESTION 38The script fails to convert a JSON variable into a Python dictionary. Which action resolves the issue?  Use a json.dumps(json_output) function  Define a json_output as a YAML object, yaml json_output  Fix the JSON syntax by modifying “attribures” to “attribures”:  Invoke a function yaml.loads(json._output ,decoder_”json”) QUESTION 39Refer to the exhibit.A network engineer traces the packet flow from the Veth991 of a blade server toward the core switch. The switch reports performance issues. What is the role of the interface Eth1/7?  IOM network interface  fabric interconnect uplink interface  IOM host interface  server interface ExplanationE1/7 is border interface, which is used as uplink. All other veth interfaces are SIF, which stands for Server Interface.QUESTION 40Refer to the exhibit.Refer to the exhibit. A network engineer is configuring the FCoE N_Port virtualization storage area network. After the initial implementation, server 11 fails to connect to the disk array. Which action resolves the issue?  On MDS interface vfc 1/1, change switchport mode configuration to VF  On N9K interface vfc11, change switchport mode configuration to NP  On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to F  On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to E QUESTION 41Refer to the exhibit.The vPC between switch1 and switch2 does not work. Which two actions resolve the problem? (Choose two.)  Configure the IP address on the interface.  Activate VLANs on the vPC.  Configure one of the switches as primary for the vPC.  Correct the configuration of the vPC peer link and the vPC peer keepalive.  Match the vPC domain ID between the two devices. Both “vPC peer link” and “Peer keepalive link” are down. So, D is correct.SW1 is using vPC domain ID 500, which SW2 is using 20. They must match. So, E is correct.QUESTION 42Refer to the exhibit.A network engineer is implementing a Cisco UCS environment. The environment consists of eight servers configured with the same service profile template and Windows 2012 installed. The VFC interfaces of five of these servers are showing the error shown in the exhibit. Which action resolves the issue?  Modify the vHBAs name in the storage connectivity policy  Configure upstream zoning  Decommission and recommission the servers  Modify the boot order in the boot policy QUESTION 43An engineer is troubleshooting issues in Cisco UCS Director. Drag and drop the possible causes from the left onto the correct issues on the right. QUESTION 44One of Cisco Nexus Series interfaces has become errdisabled with the error message “DCX-No ACK in 100 PDUs”. What is the cause of this error?  The host has not responded to the Control Sub-TLV DCBX exchanges of the switch.  The acknowledgement number in the server response has not incremented for 100 exchanges.  Cisco Discovery Protocol is disabled on the switch.  LLDP is disabled on the switch. QUESTION 45An engineer must configure Linux hosts that are deployed on Cisco UCS B-Series Servers to boot from SAN.The SAN boot policy is configured in Cisco UCS Manager, and the boot order is verified to be set as expected.However, the Linux hosts fail to boot. Which action resolves the issue?  Delete and reconfigure the boot LUN.  Delete and reconfigure the pWWN of the SAN boot target.  Remove all of the ISO images that are mounted as a virtual CD-ROM.  Remove all of the local storage that is installed. Section: Storage NetworkExplanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/2-2/ b_UCSM_CLI_Configuration_Guide_2_2/configuring_server_boot.pdf page 5QUESTION 46Refer to the exhibit.An engineer discovers that if the vPC peer link goes down, half of the devices in VLAN 20 experience connectivity issues with the external networks Which action resolves the issue?  Configure a dedicated Layer 3 link between vPC peers  Allow non-vPC VLANs on a second trunk between the two vPC peers  Add the non-vPC SVIs in the dual-active exclude VLAN list  Exclude the non-vPC VLANs from vPC peer link QUESTION 47Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right. QUESTION 48An engineer is troubleshooting a fabric discovery failure. Which two requirements must an engineer verify about switch connectivity to solve the problem? (Choose two.)  A Cisco APIC must be attached to a spine node only.  A Cisco APIC must be attached to leaf nodes.  Spine nodes must connect to other spine nodes.  A Cisco APIC must be dual-attached to two separate spine nodes.  Leaf nodes must connect to spine nodes only. QUESTION 49A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right. QUESTION 50A Cisco Nexus 9000 Series Switch crashes and fails to boot. An engineer must recover the switch and investigate the issue. The switch uses 172.20.50.213/24 IP address for management and its default gateway is 172.20.50.254. Drag and drop the steps for recovering the Cisco Nexus 9000 Series Switch from the left onto the right. Not all steps are used.Select and Place: QUESTION 51A network administrator attempts to install an application in the Cisco NX-OS Guest shell and receives an error that there is not enough space on the disk. Which command must the administrator run to increase the disk space available in the Guest shell?  guestshell growdisk rootfs [size-in-MB]  guestshell pvextend rootfs [size-in-MB]  guestshell resize rootfs [size-in-MB]  guestshell resize2fs rootfs [size-in-MB] QUESTION 52DRAG DROPDrag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.Select and Place: Section: Compute PlatformsQUESTION 53During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a “No Signal” message from the vKVM and physical connection. Which set of steps resolves the issue?  1- Disconnect the power cord2- Confirm that all cards are property seated3- Connect the power cord and power on the server  1- Power off the server and disconnect the power cord2- Confirm that all cards are property seated3- Connect the power cord and power on the server  1- Power off the server and disconnect the power cord2- Confirm that all cards are available3- Connect the power cord and power on the server  1- Disconnect the power cord2- Confirm that all cards are properly seated3- Connect the power cord Explanationhttps://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pdQUESTION 54During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a “No Signal” message from the vKVM and physical connection. Which set of steps resolves the issue?  1- Disconnect the power cord2- Confirm that all cards are property seated3- Connect the power cord and power on the server  1- Power off the server and disconnect the power cord2- Confirm that all cards are property seated3- Connect the power cord and power on the server  1- Power off the server and disconnect the power cord2- Confirm that all cards are available3- Connect the power cord and power on the server  1- Disconnect the power cord2- Confirm that all cards are properly seated3- Connect the power cord https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pdfQUESTION 55The Cisco Nexus switch is connected to a peer switch that is not running Cisco NX-OS. The switches are connected using port channel and are experiencing packet loss. Which action should be performed on the Cisco Nexus switch ports to resolve this issue?  Turn on lacp suspend-individual.  Turn on lacp graceful-convergence.  Turn off lacp graceful-convergence.  Turn off lacp suspend-individual. QUESTION 56Refer to the exhibit.A network engineer needs to capture traffic from the VMs that utilize the IOM host interface Eth1/1/23 of a Cisco UCS B-Series chassis. A traffic analyzer is used to get traffic captured from the Eth1/4 interface of the subordinate fabric interconnect. The network engineer notices that traffic is not captured on the traffic analyzer. Which action resolves the issue?  Span the traffic from the Eth 1/2 of the subordinate fabric interconnect.  Span the traffic from the Eth 1/4 of the subordinate fabric interconnect.  Span the traffic from the Eth 1/2 of the primary fabric interconnect.  Span the traffic from the Eth 1/4 of the primary fabric interconnect. QUESTION 57Refer to the exhibit.A network engineer configures an EEM script to get a syslog notification after a configuration change. This message appears when the engineer must make a new configuration to this switch. Which configuration did the engineer neglect to apply in the script for it to function properly?  event cli match ‘configure terminal’  event policy-default count 1 time 100  event syslog occurs 10  action 2.0 event-default QUESTION 58Refer to the exhibit.A web browser displays a “not secure” warning message when accessing the web interface of Cisco UCS Manager. Which action resolves the issue?  Load third-party certificate to UCS Manager.  Use the correct TCP port for HTTPS.  Use a supported web browser.  Use a supported version of UCS Manager. QUESTION 59Refer to the exhibit.A network engineer is implementing an RBAC on the Cisco Nexus 9000 Series Switch. The role called Host A fails to clear LACP counters on the port channel 20. Which configuration resolves the issue?  Permit rule number 3 and read-write L3 operation.  Delete rule 3 and create new rule 3 to allow the permit command.  Change the sequence of rule 2 and rule 3.  Delete rule 2 and create a new rule 4  Loading … Cisco 300-615 exam is a 90-minute exam that consists of 60-70 questions. 300-615 exam format includes multiple-choice and simulation questions. 300-615 exam is designed to test the candidate's ability to identify, diagnose, and resolve complex data center infrastructure issues. 300-615 exam also tests the candidate's knowledge of troubleshooting methodologies and tools.   300-615 Actual Questions Answers PDF 100% Cover Real Exam Questions: https://www.braindumpsit.com/300-615_real-exam.html --------------------------------------------------- Images: https://blog.braindumpsit.com/wp-content/plugins/watu/loading.gif https://blog.braindumpsit.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-08-15 09:52:37 Post date GMT: 2023-08-15 09:52:37 Post modified date: 2023-08-15 09:52:37 Post modified date GMT: 2023-08-15 09:52:37