This page was exported from IT Certification Exam Braindumps [ http://blog.braindumpsit.com ] Export date:Sat Apr 12 18:48:52 2025 / +0000 GMT ___________________________________________________ Title: New 2024 Realistic AD01 Dumps Test Engine Exam Questions in here [Q46-Q65] --------------------------------------------------- New 2024 Realistic AD01 Dumps Test Engine Exam Questions in here Updated Official licence for AD01 Certified by AD01 Dumps PDF Blue Prism AD01 certification exam consists of two parts; theoretical and practical. The theoretical part focuses on testing the candidate's knowledge of the Blue Prism platform, its architecture, and components. The practical part evaluates the candidate's ability to develop and implement automation solutions using the Blue Prism platform. AD01 exam is held in a controlled environment, ensuring that the candidates are tested under strict guidelines and procedures. Obtaining the Blue Prism AD01 certification is a significant achievement for individuals seeking to advance their career in the RPA industry. Blue Prism Accredited Developer Exam certification demonstrates that the individual has a comprehensive understanding of the Blue Prism platform and can develop and deploy RPA solutions that meet the needs of various organizations. Blue Prism Accredited Developer Exam certification also provides individuals with a competitive advantage in the job market, as it is recognized globally and is highly regarded by employers in the RPA industry.   NO.46 Study the process flow below:The outputs for the Get Next Case are configured below:What is the correct configuration of the Expression in the “Case-Returned” decision stage?A:B:C:D:  Option A  Option B  Option C  Option D NO.47 The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen.Which is the correct configuration to ensure the New Order screen is in focus?A)B)C)D)  Exhibit A  Exhibit B  Exhibit C  Exhibit DFor window application to ensure the new screen is in focus We need to activate the New screen as not the application. NO.48 Study the process flow below:The outputs for the Get Next Case are configured below:What is the correct configuration of the Expression in the “Case-Returned” decision stage?A:B:C:D:  Option A  Option B  Option C  Option D NO.49 Which of the following Stages can be found in Process Studio but NOT in Object Studio?         NO.50 Which of the following indicates a case in a Work Queue is an exception?         Explanation/Reference:NO.51 Study the following process flow:This is the Main Page of a simple process which calls the Page Calculation before completing.The data items are configured as follows:* X is a Number data item with an initial value of 20* Y is a Number data item with an initial value of 5* Result is a Number data item with no initial valueThe Calculation Page stage is configured as follows:The Calculation Page is as follows:The Data Items are configured as follow:* X is a Number data item with an initial value of 10* Y is a Number data item with an initial value of 5* Result is a Number data item with no initial valueThe Start Stage is configured pass through the X and Y values an input parameters The divide calculation stage expression is [X] / [Y] The end stage is configured to pass back the results value as an output parameter.What will be contained in the Result Data Item on the Main Page following the execution of the Process?  0  No Value  2  4 NO.52 A Blue Prism solution works fine when developing and testing it in Process and Object studio but when it is ran in Control Room exceptions occur because of screen elements not being found. What is the most likely cause?  The most likely cause for the errors is that your application has changed.  The most likely cause for the errors seen in Control Room is that best practice use of wait stages has not been followed.  The most likely cause for the errors is that the Object Studio action has not been published and therefore cannot be used by the Process in control room.  The most likely cause for the exceptions is that best practice exception handling has not been incorporated into the Process. ExplanationReason: This is because when we are running the process in testing and development phase at time the speed of running the process is slow, that’s why it ran properly and when we haven’t give the proper wait stage and when the process ran in control room the exception occurs as the process ran in full speed so the process is not having the time to wait.This is mentioned in the Process creation exercise or Lifecycle exercise.NO.53 Study the following configuration:Which of the following statements is correct?  When the configuration is run in Control Room, it will become stuck in an infinite loop  When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in System Manager  When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in the Control Room  When the configuration is run in Control Room, it will fail with an internal error on the first execution of the ‘Switch?’ stage with the error: Decision did not result in a yes/no answer NO.54 The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New Order screen is in focus?A:B:C:D:  Option A  Option B  Option C  Option D NO.55 Consider the following flow within an Object Studio action:The developer of this flow found that writing some credentials to the target application sometimes failed with an exception even though the element exists on the screen. He found that simply catching the exception, waiting for 2 seconds and then retrying fixed the problem.What problems do you see within the flow? (select 2 responses)  A block has not been placed around the Write stage and the Recover stage, meaning the credentials action could be unnecessarily retried if another stage further into this action throws an exception.  There is a potential for an infinite loop if the ‘Credentials’ stage keeps throwing an exception for some unforeseen reason.  The credentials stage is a read stage not a write stage.  There is not a Resume stage following the timeout of the Wait stage NO.56 The Work Queue “Customer Onboarding” has a number of Pending Items which may be tagged as“Domestic”, “Retail” or “Business”.What is the correct configuration to get the next item from the queue that is tagged either “Retail” or“Business”?  Configure “-Domestic” in the Tag Filter parameter  Configure “Retail or Business” in the Tag Filter parameter  Configure “Retail; Business” in the Tag Filter parameter  Configure “Retail + Business’ in the Tag Filter parameter Explanation/Reference:NO.57 Examine the following process flow:The Loop Orders loop is configured to loop through the Orders collection.How Many times will the ‘Process Order’ page be executed?  1  15  The loop will be infinite  It’s impossible to tell. There is no loop counter. ExplanationLoop Orders is configuring to the Orders collection and as per the diagram in the order collection there are 15 rows so the loop is run till 15 times and the process order page will executed 15 times.NO.58 Consider the following process flow from a sub-page of a process:What is the problem with this sub-page flow?  There is nothing wrong with the sub-page flow shown in this image  The sub-page process flow is missing any retry exception handling that should exist where a process calls object actions that interface with an application.  For better visibility of the process logic the flow steps shown in the image should be on the main page rather than in a sub-page of the process.  The exception stage within the flow should be removed and replaced with an End stage that returns the found data item as an output parameter. NO.59 Which of the following can you perform in the System->Workflow area of Blue Prism? (Choose all that apply.)  View the contents of a Work Queue.  Refresh a Work Queue.  Encrypt a Work Queue.  Create a Work Queue. NO.60 Which of the following statements about Business Objects is true?  It is Blue Prism best practice to include business rules within Business  A Business Object is configured in the Studio area of Blue Prism  A Business Object can be exposed to Control Room  Logging of individual stages is not configurable in Business Objects Reason: As the business object is only configure in the Object studio.Rest all other reasons are failed. NO.61 When configuring an object’s run mode which of the following is true?  Setting the run mode to foreground will give the object priority over the target system ahead of any other Business Object.  Setting the run mode to exclusive will ensure only one process runs on that resource at a time.  Setting the run mode to background will enable the object to run at the same time as foreground and background objects on the same resource.  Leaving the run mode blank will allow any number of processes and objects to run at the same time on the same resource. NO.62 The data item “Loop Counter” is a number data item and has an initial value of 0. The data item “Max Loops” is a number data item and has an initial value of 10.The two stages are configured as follows:How many times will the Loop Again stage be executed when the page is executed?  10  9  11  The loop will be infinite NO.63 Consider the following flow in an object:Which of the following statements are true?  There just needs to be a wait stage after the start stage to correct this action.  There should be a wait stage after every stage in this flow (i.e. after the navigate, read, write stages.  If during testing in object studio this flow works, no additional wait stages should be added as they will slow the interface down.  There should be an intelligent wait stage after the start stage and after any stage that cause the application we are interfacing with to change ExplanationIntelligent wait stage should always be used after every stage and that should be minute wait to overcome the lag when the application runs and on wait should only be used when some of action interfacing the screens or any updating is going on as per the best practices pdfNO.64 Exhibit:What will be the outcome after the page has run?  Data Item Output Value contains A  Data Item Output Value contains B  Data Item Output Value contains C  An Internal Exception will be thrown NO.65 How can a session variable value be updated when a process is running? (select all that apply)  By using the Internal – Session Variables business object.  By pausing the Session Variables work queue.  By updating the value in Credential Manager.  By updating the value in Control Room. ExplanationReason: Session variable values to be update only in the Control room.Below is the reference. Loading … Grab latest Blue Prism AD01 Dumps as PDF Updated: https://www.braindumpsit.com/AD01_real-exam.html --------------------------------------------------- Images: https://blog.braindumpsit.com/wp-content/plugins/watu/loading.gif https://blog.braindumpsit.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2024-02-14 09:19:40 Post date GMT: 2024-02-14 09:19:40 Post modified date: 2024-02-14 09:19:40 Post modified date GMT: 2024-02-14 09:19:40